Gypsol HTC is designed for use with both conventional heat sources and renewable technologies. It is not pipe specific and is suitable for use with any underfloor heating system and in any type of construction, subject to suitable engineering.
It is suitable for use over timber floors, Lewis decking, and more traditional concrete and masonry systems. Gypsol HTC is specially formulated to allow thinner depths than our conventional Gypsol screeds allowing just 20mm cover to heating conduits.
Gypsol HTC is suitable for all types of floor covering including not only traditional tiles, carpets, vinyl and wood floors but also with suitably formulated floor sealers such as clear epoxy coatings. Coupled with Gypsol HTC’s unrivalled and independently tested thermal conducitivity, this offers the ultimate in underfloor heating efficiency and comfort.
| Physical data | ||
|---|---|---|
| Appearance | Off white fluid mortar | |
| Density | Wet 2200kg/m3 | Dry 2000kg/m3 |
| Required Strength | C25 - F4 | Minimum binder content 800kg/m3 |
| Required Flow (EN 13454-2) | 230 - 270mm | |
| Reaction to Fire | Class A1fl Non Combustible | |
| Performance Data | ||
| Working Time | Place and finish within 3 hours of batching | |
| Foot Traffic | 24 to 48 hours | |
| Loading | 5-7 days | |
| Drying (50mm depth)[1] | At 20oC and 60% RH - 28 days | Active force drying - 13 days |
| Force Drying | Can be force dried after 7 days | |
Drying times vary dependent on screed depth, ambient conditions and suitability of the building envelope.
[1] Independently tested and verified by Action Dry Ltd. Full report available upon request
| Minimum Depth requirements | ||
|---|---|---|
| Bonded | 25mm [2] | |
| Unbonded | 30mm | |
| Floating | 35mm Domestic | 40mm Commercial |
| Acoustic | 80kg/m2 @ 40mm | |
| Cover to conduits | 25mm | |
[2] Prepare the substrate in accordance with BS8204:7:2003 using a gritted two coat epoxy resin DPM or similar.
| Bay sizes and joint requirements | ||
|---|---|---|
| Heated | ||
| Maximum Length | 20m | |
| Maximum Aspect Ratio | 6:1 | |
| Maximum Bay Size | 300m2 | |
| Movement joints should be placed at Door Thresholds, between independently controlled heating zones and where heated and unheated screeds meet. | ||
| Unheated | ||
| Maximum Bay Length | 40m | |
| Maximum Aspect Ratio | 8:1 | |
| Maximum Bay Size | 1000m2 | |